| Item |
Characteristics |
| Operating
Temperature Range(oC) |
-40~+85 |
|
Rated Voltage Range (V) |
6.3~450 |
| Nominal
capacitance range (uF) |
0.1~22000 |
| Capacitance
Tolerance(20oC,120Hz) |
+/-20% |
| Leakage
current (uA) |
| Rated
Voltage (V) |
6.3~100 |
160~450 |
| |
I<=0.01CV or
3 whichever is greater.( at 20oC,after 2 minutes) |
I<=0.03CV+10
(at 20oC,after 2 minutes ) |
C: Nominal capacitance (uF)
V: Rated voltage (V) |
| Dissipation
Factor(20oC,120Hz) |
| Rated
Voltage (V) |
6.3 |
10 |
16 |
25 |
35 |
50 |
63 |
100 |
160~250 |
350~450 |
| D.F. |
0.22 |
0.19 |
0.16 |
0.14 |
0.12 |
0.10 |
0.09 |
0.08 |
0.18 |
0.20 |
when nominal
capacitance is over 1000uF D.F. shall be added
0.02 to the listed
value with increase of every 1000 uF
|
| Temperature
Stability(120Hz) |
| Rated
Voltage (V) |
6.3 |
10 |
16~50 |
63 |
100 |
160 |
200 |
250 |
350 |
400 |
450 |
| Impedance
Ratio |
Z-25oC/Z+20oC |
|
|
|
|
|
6 |
8 |
8 |
15 |
| Z-40oC/Z+20oC |
8 |
6 |
4 |
3 |
3 |
|
|
|
| Load
Life(+85oC) |
| Time |
2000
hours. |
| Leakage
Current |
Not
more than the specified value. |
| Capacitance
Change |
Within
+/-20% of the initial value. |
| Dissipation
Factor |
Not
more than 200% of the specified value. |
|
| Shelf
Life(+85oC) |
| Time |
1000
hours. |
| Leakage
Current |
Not
more than the specified value. |
| Capacitance
Change |
Within
+/-20% of the initial value. |
| Dissipation
Factor |
Not
more than 200% of the specified value. |
After test: Rated voltage to be applied for
30 minutes, 24 to 48 hours before measurement.
|