| Item |
Characteristics |
| Operating
Temperature Range(oC) |
-40~+85 |
|
Rated Voltage Range (V) |
10~50 |
| Nominal
capacitance range (uF) |
0.47~47 |
| Capacitance
Tolerance(20oC,120Hz) |
+/-20% |
| Leakage
current (uA) |
I<=0.01CV+3
C: Nominal Capacitance (uF) V: Rated Voltage (V) |
| Dissipation
Factor(20oC,120Hz) |
| Rated
Voltage (V) |
10 |
16 |
25 |
50 |
| D.F. |
0.10 |
0.10 |
0.10 |
0.08 |
|
| Temperature
characteristics(120Hz) |
Z-40oC/Z+20oC<=4
|
| Load
Life(+85oC) |
| Time |
1000
hours. |
| Leakage
Current |
Not
more than the specified value. |
| Capacitance
Change |
Within
+/-20% of the initial value. |
| Dissipation
Factor |
Not
more than 200% of the specified value. |
|
| Shelf
Life(+85oC) |
| Time |
1000
hours. |
| Leakage
Current |
Not
more than the specified value. |
| Capacitance
Change |
Within
+/-20% of the initial value. |
| Dissipation
Factor |
Not
more than 200% of the specified value. |
After test: Rated voltage to be applied for