| Item |
Characteristics |
| Operating Temperature Range(oC) |
-40-+85 |
| Rated Voltage Range (V) |
6.3~100 |
| Nominal capacitance range (uF) |
0.47~15000 |
| Capacitance Tolerance(20oC, 120Hz) |
+/-20% |
| Leakage
Current (uA) |
I<=0.001CV or 4uA whichever is greater, (at 20oC,after 2 minutes)
C: Nominal Capacitance (uF), V: Rated Voltage (V) |
|
Dissipation Factor(20oC, 120Hz) |
| Rated voltage (v) |
6.3 |
10 |
16 |
25 |
35 |
50 |
63 |
100 |
| D.F. |
0.30 |
0.25 |
0.19 |
0.16 |
0.14 |
0.12 |
0.10 |
0.10 |
when nominal capacitance
is over 1000uF D.F. shall be added 0.02 to the listed
value with increase of every 1000 uF
|
| Load Life(+85oC) |
| Time |
2000hours |
| Leakage current |
Initial specified value or less |
| Capacitance change |
within+/-20% of initial value |
| Dissipation |
Not more than 150% of the specified value. |
|
| Shelf Life (+85oC) |
| Time |
500hours |
| Leakage current |
Initial specified value or less |
| Capacitance change |
within+/-20% of initial value |
| Dissipation |
Not more than 150% of the specified value. |
After test: Rated voltage to be applied for 30 minutes, 24 to 48 hours before measurement. |