Item |
Characteristics |
|
Operating Temperature Range(oC) |
-40~+105 |
|
Rated Voltage Range (V) |
200~400 |
|
Nominal capacitance range (uF) |
1~33 |
|
Capacitance Tolerance(20oC,120Hz) |
+/-20%
|
| Leakage current (uA) |
I<=0.03CV
or 4 whichever is greater. |
CV<=1000:I<=0.1CV+40
CV>1000:I<=0.04CV+100 |
|
C: Nominal Capacitance
(uF) V: Rated Voltage (V)
|
|
Dissipation Factor(20oC,120Hz) |
| Rated
voltage (v) |
200 |
250 |
400 |
| D.F. |
0.09 |
0.09 |
0.10 |
|
|
Load Life(+105oC) |
| Time |
2000
hours |
| Leakage current |
Not
more than the specified value. |
| Capacitance Change |
within +/-20% of the initial value. |
| Dissipation Factor |
Not
more than 200% of the specified value. |
|
|
Shelf Life(+105oC) |
| Time |
1000
hours |
|
Leakage current |
Not more than the
specified value. |
| Capacitance Change |
within +/-20% of the initial value. |
| Dissipation Factor |
Not
more than 200% of the specified value. |
After test:
Rated voltage to be applied for 30 minutes,24 to
48 hours before measurement.
|