|
Item |
Characteristics |
- |
|
Operating
Temperature Range(oC) |
-40~+85 |
|
Rated
Voltage Range (V) |
10~100 |
|
Nominal Capacitance Range (uA) |
1000~220000 |
|
Capacitance
Tolerance(20oC,120Hz) |
+/-20% |
|
Leakage
current(20oC)
|
1<=0.006CV+4(uA)
or 5mA(Whichever is smaller)(after 5 minutes)
C: Nominal capacitance (uF) V: Rated voltage (V)
|
|
Dissipation
Factor(20oC,120Hz) |
|
Rated
Voltage (V) |
10 |
16 |
25 |
50 |
63 |
100 |
|
D.F. |
D=35 |
0.50 |
0.40 |
0.30 |
0.25 |
0.20 |
0.15 |
|
D=50 |
0.75 |
0.50 |
0.40 |
0.30 |
0.25 |
0.20 |
|
D=64 |
1.00 |
0.75 |
0.50 |
0.35 |
0.30 |
0.25 |
|
D=76 |
1.50 |
1.00 |
0.75 |
0.50 |
0.40 |
0.35 |
|
|
Load
Life(85oC) |
|
Time |
2000
hours. |
|
Leakage
Current |
Not
more than the initial specified value. |
|
Capacitance
Change |
Within
+/-20% of the initial value. |
|
Dissipation
Factor |
Not
more than 200% of the specified value |
|
|
Shelf
Life(85oC) |
|
Time |
500
hours. |
|
Leakage
Current |
Not
more than the initial specified value. |
|
Capacitance
Change |
Within
+/-15% of the initial value. |
|
Dissipation
Factor |
Not
more than 150% of the specified value |
After
test: Rated voltage to be applied for
30 minutes, 24 to 48 hours before measurement.
|